Forensic Bloodstain Detection

BlueStar Forensic Medium Kit

Luminol-based chemiluminescent reagent for the detection of latent, washed, or cleaned bloodstains. Compact two-application kit designed for mobility and active field use. For forensic use only.

BlueStar Forensic Medium Kit

Compact, Reliable, Field-Ready Bloodstain Detection

The BlueStar Forensic Medium Kit provides crime scene investigators with a convenient, easy-to-use solution for detecting invisible blood traces. Designed for mobility, the kit contains two separate applications (250 mL / 8 oz each), suited to active field deployment where a full-size kit is impractical to carry.

The reagent is prepared by dissolving the supplied tablets in solution, then applied to the surface under examination — a bright chemiluminescent glow indicates a strong likelihood of blood, even where the stain has been cleaned or is not visible to the naked eye.

BlueStar Forensic reacts with blood broadly. To support differentiation of human origin, a confirmatory rapid immunochromatographic test should be used as a follow-up step, with final confirmation conducted in a forensic laboratory per validated SOP. The reagent is non-destructive to DNA and supports subsequent DNA profiling.

Manufacturer: BlueStar Forensic — bluestar-forensic.com  ·  Australian Distributor: Advanced Biotech Pty Ltd

2 Applications
Kit Format
Any Surface
Substrate Compatibility
DNA Safe
Sample Integrity
Forensic Use Only
Regulatory Category

Intended Use

Defined scope of application for the BlueStar Forensic Full Kit in professional forensic and crime scene settings.

Latent Bloodstain Detection — Field Use

The BlueStar Forensic Medium Kit is intended for the detection of minute, diluted, or thoroughly cleaned blood traces at a suspected crime scene or on forensic exhibits, in a compact format suited to mobile and active field deployment. The chemiluminescent reaction produces a bright blue glow visible to the naked eye, without requiring total darkness.

The kit is intended for use by trained forensic scientists, crime scene investigators, and law enforcement personnel operating in accordance with validated standard operating procedures.

Scope & Limitations

Indicated for: Screening of surfaces including metal, plastic, and fabric for the presence of blood, including washed, diluted, or aged bloodstains.

Species specificity: BlueStar Forensic reacts with blood broadly and is not species-specific. Confirmation of human origin requires a follow-up immunochromatographic test, with final confirmation conducted in a forensic laboratory.

Not indicated for: Clinical diagnostic use, or as a standalone confirmatory test for human blood. Certain food residues or chemical substances may produce false positives; appropriate training is required for correct interpretation. For forensic use only.

Instructions for Use

The BlueStar Forensic Full Kit follows a straightforward preparation and application workflow suited to crime scene conditions.

Reagent Preparation

Dissolve 2 oxidant tablets in one of the supplied 250 mL bottles of chemiluminescent solution. The kit provides material for two separate applications.

Spray Head Setup

Screw the adjustable spray head onto the bottle and set the spray pattern as required for the area being examined.

Application & Observation

Spray the prepared solution onto the surface under examination. A positive chemiluminescent reaction produces a bright blue glow at sites of blood deposition, visible without requiring total darkness. The reaction is stable and long-lasting, allowing time for observation and photography.

Documentation & Follow-Up Testing

Photograph and document luminescent areas per laboratory SOP. Where confirmation of human origin is required, proceed with a validated immunochromatographic rapid test, followed by final confirmatory analysis in a forensic laboratory.

Applications

Forensic settings where the BlueStar Forensic Full Kit is used for bloodstain detection and crime scene examination.

Crime Scene Investigation

Detection of latent or cleaned bloodstains at suspected crime scenes, including surfaces that have been washed, painted over, or otherwise concealed.

Violent Crime & Homicide Casework

Screening of scenes, vehicles, and exhibits for trace blood evidence in assault, homicide, and other violent crime investigations.

Cold Case Re-examination

Re-screening of archived scenes or exhibits where bloodstain evidence may have degraded, been cleaned, or was not detected using earlier methods.

Forensic Laboratory Training

Use of BlueStar Forensic Training Tablets to train personnel in distinguishing true blood reactions from potential false positives prior to live casework deployment.

Vehicle & Weapon Examination

Screening of vehicle interiors, weapons, and other evidentiary items for trace bloodstains not visible to the naked eye.

DNA Evidence Triage

Identification of probative bloodstain locations to guide targeted DNA sampling, since the reagent is non-destructive to DNA.

Key Benefits

Stronger Luminescence

Longer-Lasting Reaction

High Sensitivity

Total Darkness Not Required

No Additional Equipment Needed

Fully Soluble

Stable Over Time

Non-Destructive to DNA

Technical Specifications

BlueStar Forensic Full Kit Technical Specifications
Product nameBlueStar Forensic — Medium Kit
Product codeBL-FOR-250
Reagent typeLuminol-based chemiluminescent reagent
Detection methodChemiluminescence — bright blue glow on contact with blood
Kit contents2 x 2 oxidant tablets (for 2 applications); 2 bottles of 250 mL (8 oz) chemiluminescent solution; 1 adjustable spray head; 1 instruction sheet
Substrate compatibilityMetal, plastic, fabric, and other surfaces
DNA compatibilityNon-destructive to DNA
StorageStore in a dark, dry place between 4°C and 30°C (39°F to 86°F)
Dimensions21.5 x 14 x 7.5 cm (8.5 x 5.5 x 3 in)
Weight690 grams (24.3 oz)
Regulatory categoryForensic — for forensic use only
ManufacturerBlueStar Forensic
Australian distributorAdvanced Biotech Pty Ltd
For Forensic Use Only
Cat B — Forensic

The BlueStar Forensic Medium Kit is a forensic screening reagent. For forensic use only. This product is not approved or intended for clinical diagnostic use. A positive chemiluminescent reaction indicates a strong likelihood of blood presence and is not species-specific; confirmation of human origin requires a follow-up immunochromatographic test, with final confirmation conducted by a forensic laboratory.

Results must be interpreted by qualified forensic scientists or crime scene personnel operating in accordance with validated standard operating procedures. Australian Distributor: Advanced Biotech Pty Ltd.

Enquire About the BlueStar Forensic Medium Kit

Contact Advanced Biotech Pty Ltd to request pricing, pack sizes, availability, and technical documentation for the BlueStar Forensic range in Australia.