BlueStar Forensic Tablets — 4 Applications
Compact, lightweight tablet refill for preparing BlueStar Forensic working solution. Four pairs of tablets for flexible 125 mL to 500 mL applications. For forensic use only.
Flexible Tablet Refill for Working Solution Preparation
BlueStar Forensic Tablets — 4 Applications is a compact, lightweight tablet refill providing material to prepare from 125 mL up to 500 mL (4 to 16 oz) of BlueStar Forensic working solution. Each box contains four pairs of individually sealed tablets, allowing investigators to prepare either four individual 125 mL applications or combine all four pairs into a single 500 mL volume as needed.
A positive chemiluminescent reaction indicates the probable presence of blood, even where the stain is invisible to the naked eye or has been cleaned.
BlueStar Forensic reacts with blood broadly. To support differentiation of human origin, a confirmatory rapid immunochromatographic test should be used as a follow-up step, with final confirmation conducted in a forensic laboratory per validated SOP.
Manufacturer: BlueStar Forensic — bluestar-forensic.com · Australian Distributor: Advanced Biotech Pty Ltd
Intended Use
Defined scope of application for the BlueStar Forensic Full Kit in professional forensic and crime scene settings.
Flexible-Volume Bloodstain Detection
BlueStar Forensic Tablets — 4 Applications is intended as a refill or flexible-volume option for the detection of minute, diluted, or thoroughly cleaned blood traces at a suspected crime scene or on forensic exhibits. The format allows investigators to scale working solution volume to the size of the area under examination.
This product requires a spray bottle (not supplied) to prepare and apply the working solution. It is intended for use by trained forensic scientists, crime scene investigators, and law enforcement personnel operating in accordance with validated standard operating procedures.
Scope & Limitations
Indicated for: Screening of surfaces including metal, plastic, and fabric for the presence of blood, including washed, diluted, or aged bloodstains.
Species specificity: BlueStar Forensic reacts with blood broadly and is not species-specific. Confirmation of human origin requires a follow-up immunochromatographic test, with final confirmation conducted in a forensic laboratory.
Not indicated for: Clinical diagnostic use, or as a standalone confirmatory test for human blood. Certain food residues or chemical substances may produce false positives; appropriate training is required for correct interpretation. For forensic use only.
Instructions for Use
The BlueStar Forensic Full Kit follows a straightforward preparation and application workflow suited to crime scene conditions.
Reagent Preparation
Dissolve one pair of tablets (white and beige) in a 125 mL sprayer (not supplied). For larger working volumes, multiple tablet pairs may be combined up to a 500 mL total volume.
Spray Head Setup
Screw the adjustable spray head onto the bottle and set the spray pattern as required for the area being examined.
Application & Observation
Spray the prepared solution onto the surface under examination. A positive chemiluminescent reaction produces a bright blue glow at sites of blood deposition, visible without requiring total darkness. The reaction is stable and long-lasting, allowing time for observation and photography.
Documentation & Follow-Up Testing
Photograph and document luminescent areas per laboratory SOP. Where confirmation of human origin is required, proceed with a validated immunochromatographic rapid test, followed by final confirmatory analysis in a forensic laboratory.
Applications
Forensic settings where the BlueStar Forensic Full Kit is used for bloodstain detection and crime scene examination.
Crime Scene Investigation
Detection of latent or cleaned bloodstains at suspected crime scenes, including surfaces that have been washed, painted over, or otherwise concealed.
Violent Crime & Homicide Casework
Screening of scenes, vehicles, and exhibits for trace blood evidence in assault, homicide, and other violent crime investigations.
Cold Case Re-examination
Re-screening of archived scenes or exhibits where bloodstain evidence may have degraded, been cleaned, or was not detected using earlier methods.
Forensic Laboratory Training
Use of BlueStar Forensic Training Tablets to train personnel in distinguishing true blood reactions from potential false positives prior to live casework deployment.
Vehicle & Weapon Examination
Screening of vehicle interiors, weapons, and other evidentiary items for trace bloodstains not visible to the naked eye.
DNA Evidence Triage
Identification of probative bloodstain locations to guide targeted DNA sampling, since the reagent is non-destructive to DNA.
Key Benefits
Stronger Luminescence
Longer-Lasting Reaction
High Sensitivity
Total Darkness Not Required
No Additional Equipment Needed
Fully Soluble
Stable Over Time
Non-Destructive to DNA
Technical Specifications
| Product name | BlueStar Forensic — Tablets 4 Applications |
|---|---|
| Product code | BL-FOR-TAB4 |
| Reagent type | Luminol-based chemiluminescent reagent |
| Detection method | Chemiluminescence — bright blue glow on contact with blood |
| Kit contents | 4 pairs of individually sealed tablets (reagent and oxidant); 1 instruction sheet. Spray bottle not supplied. |
| Substrate compatibility | Metal, plastic, fabric, and other surfaces |
| DNA compatibility | Non-destructive to DNA |
| Storage | Store in a dark, dry place between 4°C and 30°C (39°F to 86°F) |
| Dimensions | 11.6 x 5.7 x 2.4 cm (4.6 x 2.3 x 1 in) |
| Weight | 26 grams (0.9 oz) |
| Regulatory category | Forensic — for forensic use only |
| Manufacturer | BlueStar Forensic |
| Australian distributor | Advanced Biotech Pty Ltd |
Downloads
Safety Data Sheets for the BlueStar Forensic Full Kit, available under EU REACH and US HCS regulations.
Safety Data Sheets — EU (REACH)
Safety Data Sheets — US (HCS)
Other Documentation
BlueStar Forensic Tablets — 4 Applications is a forensic screening reagent. For forensic use only. This product is not approved or intended for clinical diagnostic use. A positive chemiluminescent reaction indicates a strong likelihood of blood presence and is not species-specific; confirmation of human origin requires a follow-up immunochromatographic test, with final confirmation conducted by a forensic laboratory.
Results must be interpreted by qualified forensic scientists or crime scene personnel operating in accordance with validated standard operating procedures. Australian Distributor: Advanced Biotech Pty Ltd.
Enquire About BlueStar Forensic Tablets — 4 Applications
Contact Advanced Biotech Pty Ltd to request pricing, pack sizes, availability, and technical documentation for the BlueStar Forensic range in Australia.
Related Forensic Products
Explore the full forensic diagnostics range for blood and body fluid identification.
SERATEC HemDirect
Forensic lateral flow test for the detection of human hemoglobin in stain extracts. Species-specific confirmation following BlueStar screening.
PMB Test
Duplex forensic test for human hemoglobin and D-dimer, supporting differentiation of peripheral and menstrual blood.
PSA Semiquant
Semiquantitative forensic test for PSA/p30 detection in biological stain extracts.
